Gas cylinder duration
Awaiting inputs — enter values and issue a record. Empty slots below print as a blank worksheet.
Field slots
Turns a marked free-gas volume or an idealised cylinder estimate, entered flow and arc-on duty into gas-on and elapsed planning minutes — the cylinder supplier’s data outranks every figure here.
Classification Planning estimate
Gas cylinder duration
Awaiting inputs — enter values and issue a record. Empty slots below print as a blank worksheet.
Field slots
An idealised 50 L water-capacity cylinder from 200 bar down to a 20 bar reserve gives ≈ 9,000 L of usable free gas; at 15 L/min that is 600 gas-on minutes, and at a 0.5 arc-on duty fraction ≈ 1,200 elapsed minutes — 20 hours.
Gas cylinder duration
≈ 1 200 min elapsed at the entered duty
Entered assumptions
Planning figures
Planning support only — verify against nameplate/manufacturer data.
Mode A takes the marked or entered free-gas volume directly. Mode B idealises the cylinder: usable free gas L ≈ water capacity L × (start bar − reserve bar). Both modes then share two lines:
Worked figures: 50 L × (200 − 20) bar = 9,000 L of idealised usable gas; at 15 L/min, 600 gas-on minutes; at a 0.5 arc-on duty fraction, 1,200 elapsed minutes — 20 hours.